{"created":"2023-07-25T10:28:04.132929+00:00","id":816,"links":{},"metadata":{"_buckets":{"deposit":"66efa45c-75e7-458d-8f15-6ad365ff40b7"},"_deposit":{"created_by":2,"id":"816","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"816"},"status":"published"},"_oai":{"id":"oai:it-hiroshima.repo.nii.ac.jp:00000816","sets":["1:18:378"]},"author_link":["3821","3823","3824","3825","3822","3818","3819","3820"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-02","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"247","bibliographicPageStart":"241","bibliographicVolumeNumber":"43","bibliographic_titles":[{"bibliographic_title":"広島工業大学紀要. 研究編"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In the previous paper, we improved a substructure online system for investigating the restoring force characteristics of exposed column-base. This substructure online system and interface of CSA ( Collaborative structural analysis ) forms a collaborative seismic performance evaluation system. This system enables collaboration among researchers by linking their programs and experimental systems through the Internet. As participants can shear data such as interactions between structural members, distribution of seismic loading and overall failure mode of building structures, it makes it very easy to investigate the seismic performance evaluation using the sophisticated knowledge of participants. Hence, we call it a collaborative seismic performance evaluation ( CSPE ). Also, the hysteretic damper is used to use the building frame in seismic area. In this paper, we evaluate the seismic performance of building frame with a shear panel dampers using this CSPE system. Evaluation results show validity and possibility of the presented CSPE system.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"広島工業大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11599110","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13469975","subitem_source_identifier_type":"ISSN"}]},"item_10002_subject_21":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"524.6","subitem_subject_scheme":"NDC"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"玉井, 宏章"},{"creatorName":"タマイ, ヒロユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高松, 隆夫"},{"creatorName":"タカマツ, タカオ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山西, 央朗"},{"creatorName":"ヤマニシ, テルアキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3820","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"多田, 元英"},{"creatorName":"タダ, モトヒデ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3821","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tamai, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3822","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takamatsu, Takao","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3823","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamanishi, Teruaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tada, Motohide","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3825","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-30"}],"displaytype":"detail","filename":"kiyo43241.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kiyo43241.pdf","url":"https://it-hiroshima.repo.nii.ac.jp/record/816/files/kiyo43241.pdf"},"version_id":"35ffe043-9fb6-4db0-bc19-f57d2995b841"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"collaborative seismic performance evaluation","subitem_subject_scheme":"Other"},{"subitem_subject":"shear panel damper","subitem_subject_scheme":"Other"},{"subitem_subject":"Internet","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"せん断パネルダンパー付鉄骨架構の統合化耐震性能評価に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"せん断パネルダンパー付鉄骨架構の統合化耐震性能評価に関する研究"},{"subitem_title":"Collaborative Seismic Performance Evaluation of Steel Structure with Shear Panel Damper","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["378"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-30"},"publish_date":"2023-03-30","publish_status":"0","recid":"816","relation_version_is_last":true,"title":["せん断パネルダンパー付鉄骨架構の統合化耐震性能評価に関する研究"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-07-25T10:39:15.909440+00:00"}