{"created":"2023-07-25T10:27:59.926931+00:00","id":740,"links":{},"metadata":{"_buckets":{"deposit":"0bb4074c-3543-426f-b59f-5a1304d9ab6f"},"_deposit":{"created_by":2,"id":"740","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"740"},"status":"published"},"_oai":{"id":"oai:it-hiroshima.repo.nii.ac.jp:00000740","sets":["1:18:376"]},"author_link":["3360","3365","3363","3368","3364","3369","3366","3371","3367","3361","3362","3370"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"141","bibliographicPageStart":"133","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"広島工業大学紀要. 研究編"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have proposed the rehabilitation system of RC frame using hysteretic damper installed in beam lower space. To make damper effective, it is desirerable to make the damper strong. The system has limitation of damper’s strength because shear strength of RC frame joint is very low in ordinary old building. To solve the difficulty, we propose the outer steel frame with the damper installed in beam lower and upper space. We performed the cyclic loading tests on scaled RC frame with the outer steel frame with dampers to show the availability of the present system. From these results, conclusions and remarks are drawn as follows. 1) Four hysteretic dampers yield within small story drift, so that the system absorbs the seismic energy effectively. 2) The system improves the shear strength of RC frame, so that we can install the stronger damper.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"広島工業大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11599110","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13469975","subitem_source_identifier_type":"ISSN"}]},"item_10002_subject_21":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"524.91","subitem_subject_scheme":"NDC"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"玉井, 宏章"},{"creatorName":"タマイ, ヒロユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3360","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高松, 隆夫"},{"creatorName":"タカマツ, タカオ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3361","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"檜谷本, 浩二"},{"creatorName":"ヒヤモト, コウジ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3362","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尾木, 靖夫"},{"creatorName":"オギ, ヤスオ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3363","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原田, 秀秋"},{"creatorName":"ハラダ, ヒデアキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3364","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森下, 邦宏"},{"creatorName":"モリシタ, クニヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3365","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tamai, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3366","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takamatsu, Takao","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3367","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiyamato, Koji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3368","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ogi, Yasuo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3369","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Harada, Hideaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3370","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Morishita, Kunihiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3371","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-30"}],"displaytype":"detail","filename":"kenkyuhen41133.pdf","filesize":[{"value":"583.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kenkyuhen41133.pdf","url":"https://it-hiroshima.repo.nii.ac.jp/record/740/files/kenkyuhen41133.pdf"},"version_id":"a09ac264-7bdd-4f59-9156-84c427fa1a42"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"RC frame","subitem_subject_scheme":"Other"},{"subitem_subject":"Outer steel frame","subitem_subject_scheme":"Other"},{"subitem_subject":"Hysteretic damper","subitem_subject_scheme":"Other"},{"subitem_subject":"Cyclic loading test","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"外付け鉄骨のはり上下空間を利用したRC建物制震補強システムの機構について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"外付け鉄骨のはり上下空間を利用したRC建物制震補強システムの機構について"},{"subitem_title":"Mechanism on Rehabilitated RC Frame U sing Hysteretic Damper lnstalled in Beam Upper and Lower Space of Outer Steel Frame","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["376"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-30"},"publish_date":"2023-03-30","publish_status":"0","recid":"740","relation_version_is_last":true,"title":["外付け鉄骨のはり上下空間を利用したRC建物制震補強システムの機構について"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-07-25T10:41:09.181337+00:00"}