{"created":"2023-07-25T10:27:56.769307+00:00","id":683,"links":{},"metadata":{"_buckets":{"deposit":"dc050ae3-c2c7-417f-9d53-ddc0ea46f5de"},"_deposit":{"created_by":2,"id":"683","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"683"},"status":"published"},"_oai":{"id":"oai:it-hiroshima.repo.nii.ac.jp:00000683","sets":["1:18:373"]},"author_link":["3017","3016","3014","3015"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-02","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"128","bibliographicPageStart":"121","bibliographicVolumeNumber":"38","bibliographic_titles":[{"bibliographic_title":"広島工業大学紀要. 研究編"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Shaking table test of wooden framed structures was conducted under light,moderate or heavy dead load. Fundamental dynamic behavior of one-story,one-bay wooden framed structure with plywood wall was investigated. This test is focusing on changes of damage level,natural period,response magnification factor and damping factor under earthquake load with stepwise increasing input accelerations. Dynamic response analysis of wooden structures has been done,in which combination models of tri-linear Masing type and slip type for restoring-force characteristics were employed,and the earthquake acceleration level in which the specimen experienced plastic deformation is examined. Seismic property of wooden framed structures was evaluated from static horizontal loading test to make models for hysteresis loops.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"広島工業大学"}]},"item_10002_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://ci.nii.ac.jp/naid/40006127116/"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/40006127116/","subitem_relation_type_select":"URI"}}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11599110","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13469975","subitem_source_identifier_type":"ISSN"}]},"item_10002_subject_21":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"524.91","subitem_subject_scheme":"NDC"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩井, 哲"},{"creatorName":"イワイ, サトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3014","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松森, 博孝"},{"creatorName":"マツモリ, ヒロタカ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3015","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwai, Satoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3016","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsumori, Hirotaka","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"3017","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-30"}],"displaytype":"detail","filename":"kenkyuhen38121.pdf","filesize":[{"value":"494.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kenkyuhen38121.pdf","url":"https://it-hiroshima.repo.nii.ac.jp/record/683/files/kenkyuhen38121.pdf"},"version_id":"fe7cd50f-fd82-434f-bb63-56cf186b6425"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"wooden framed structures with plywood wall","subitem_subject_scheme":"Other"},{"subitem_subject":"shaking table test","subitem_subject_scheme":"Other"},{"subitem_subject":"dead load","subitem_subject_scheme":"Other"},{"subitem_subject":"natural period","subitem_subject_scheme":"Other"},{"subitem_subject":"response magnification factor","subitem_subject_scheme":"Other"},{"subitem_subject":"damping factor","subitem_subject_scheme":"Other"},{"subitem_subject":"damage evaluation","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"振動台加振実験による合板壁付木造軸組架構の地震時損傷評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"振動台加振実験による合板壁付木造軸組架構の地震時損傷評価"},{"subitem_title":"Earthquake damage evaluation of wooden framed structures with plywood wall by shaking table test","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["373"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-30"},"publish_date":"2023-03-30","publish_status":"0","recid":"683","relation_version_is_last":true,"title":["振動台加振実験による合板壁付木造軸組架構の地震時損傷評価"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-07-25T10:42:42.680407+00:00"}