{"created":"2023-07-25T10:27:39.392978+00:00","id":375,"links":{},"metadata":{"_buckets":{"deposit":"2a1f4e7c-96d5-4b79-a228-5f0ce19ded72"},"_deposit":{"created_by":2,"id":"375","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"375"},"status":"published"},"_oai":{"id":"oai:it-hiroshima.repo.nii.ac.jp:00000375","sets":["1:17:187"]},"author_link":["1796","1795"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1980","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"99","bibliographicPageStart":"95","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"広島工業大学研究紀要"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The paper describes a simple method of flow velocity measurement. This method has a merit that no calibration is required under the measuring conditions in order to apply for efficient measurement. The principle is based on application of electrolyzed material for at racer, which moves with the flow. The movement is represented numerically by a time interval when the tracer moves along the detecting electrode of the probe. The experiment confirming the principle and an example of application for a test channel are described.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"広島工業大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN0021271X","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03851672","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"玉野, 和保"},{"creatorName":"タマノ, カズホ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"1795","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tamano, Kazuho","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1796","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-30"}],"displaytype":"detail","filename":"kenkyukiyo14095.pdf","filesize":[{"value":"224.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kenkyukiyo14095.pdf","url":"https://it-hiroshima.repo.nii.ac.jp/record/375/files/kenkyukiyo14095.pdf"},"version_id":"f8fffd37-1fbf-4541-93cc-eb23cd4eddb4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"探針によるディジタルフローベロシメータの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"探針によるディジタルフローベロシメータの開発"},{"subitem_title":"Development of Digital Flow Velocimeter by Using Probe","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["187"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-30"},"publish_date":"2023-03-30","publish_status":"0","recid":"375","relation_version_is_last":true,"title":["探針によるディジタルフローベロシメータの開発"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-07-25T10:51:14.596841+00:00"}