{"created":"2023-07-25T10:28:15.166004+00:00","id":1013,"links":{},"metadata":{"_buckets":{"deposit":"cc086cf0-3beb-4dc3-8ab0-b99466a60bad"},"_deposit":{"created_by":2,"id":"1013","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"1013"},"status":"published"},"_oai":{"id":"oai:it-hiroshima.repo.nii.ac.jp:00001013","sets":["1:18:386"]},"author_link":["4906","4907"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-02","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"40","bibliographicPageStart":"33","bibliographicVolumeNumber":"51","bibliographic_titles":[{"bibliographic_title":"広島工業大学紀要. 研究編"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study aims to investigate load-deformation capacity of the walls including with three sets of crossed diagonal timber members under earthquake, in order to use earthquake-resistant improvement of the existing wooden houses. Two types of three braced wall specimens installed wooden frames, totally six specimens, were tested under repeated static loading horizontally, simulated earthquake load, in relative story-drift from 1/450 rad to 1/10 rad. The diagonal members like braces bear only compression force and are expected to perform axial ductility. It shows that relatively high earthquake resistance of the wall magnification (load carrying capacity), from 2.7 to 4.5, is obtained. The load at the specific deformation of 1/120rad story-drift in elastic region and the ultimate load capacity based on the structure properties coefficient Ds are comparable, consequently the wall gives the good balance in both elastic and plastic regions.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"広島工業大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11599110","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13469975","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩井, 哲"},{"creatorName":"イワイ, サトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Iwai, Satoshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-30"}],"displaytype":"detail","filename":"research51_033-040.pdf","filesize":[{"value":"7.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"research51_033-040.pdf","url":"https://it-hiroshima.repo.nii.ac.jp/record/1013/files/research51_033-040.pdf"},"version_id":"75dade20-9b25-4946-924f-9ac6af276498"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Wooden Frame Structure","subitem_subject_scheme":"Other"},{"subitem_subject":"Wall Amount Multiplier","subitem_subject_scheme":"Other"},{"subitem_subject":"Static Loading Test","subitem_subject_scheme":"Other"},{"subitem_subject":"Failure Property","subitem_subject_scheme":"Other"},{"subitem_subject":"Earthquake Resistant Improvement","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"短い軸組斜材を組み込んだ木造耐震改修用壁体の水平力載荷実験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"短い軸組斜材を組み込んだ木造耐震改修用壁体の水平力載荷実験"},{"subitem_title":"Horizontal loading tests of wooden framed walls for earthquake-resistant improvement using short diagonal members","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["386"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-30"},"publish_date":"2023-03-30","publish_status":"0","recid":"1013","relation_version_is_last":true,"title":["短い軸組斜材を組み込んだ木造耐震改修用壁体の水平力載荷実験"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-07-25T10:35:20.263547+00:00"}