<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-11T16:44:54Z</responseDate>
  <request verb="GetRecord" identifier="oai:it-hiroshima.repo.nii.ac.jp:00001179" metadataPrefix="oai_dc">https://it-hiroshima.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:it-hiroshima.repo.nii.ac.jp:00001179</identifier>
        <datestamp>2023-07-25T10:31:58Z</datestamp>
        <setSpec>1:18</setSpec>
        <setSpec>1:18:394</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>観測記録に基づく RC 造建物の振動特性と耐震補強効果に関する調査研究\n—広島工業大学本館棟を対象として—</dc:title>
          <dc:title>Evaluation of Dynamic Properties and Seismic Resistance of The RC Building \nBefore and After Retro_tting Based on Microtremor Measurements\n—Using The Main O_ce Building in Hiroshima Institute of Technology—</dc:title>
          <dc:creator>山下, 航平</dc:creator>
          <dc:creator>ヤマシタ, コウヘイ</dc:creator>
          <dc:creator>渡壁, 守正</dc:creator>
          <dc:creator>ワタカベ, モリマサ</dc:creator>
          <dc:creator>久保川, 淳司</dc:creator>
          <dc:creator>クボカワ, ジュンジ</dc:creator>
          <dc:creator>光井, 周平</dc:creator>
          <dc:creator>ミツイ, シュウヘイ</dc:creator>
          <dc:creator>黒河, 真</dc:creator>
          <dc:creator>クロカワ, マコト</dc:creator>
          <dc:creator>Kohei, YAMASHITA</dc:creator>
          <dc:creator>Morimasa, WATAKABE</dc:creator>
          <dc:creator>Junji, KUBOKAWA</dc:creator>
          <dc:creator>Shuhei, MITSUI</dc:creator>
          <dc:creator>Makoto, KUROKAWA</dc:creator>
          <dc:subject>Seismic Reinforcement, Dynamic Characteristics, Microtremor Measurement, Structural Health Monitoring System</dc:subject>
          <dc:description>application/pdf</dc:description>
          <dc:description>In order to verify the seismic reinforcement e_ect to the RC building quantitatively, Microtremor measurement was carried out for the main building before and after the reinforcement and compared the dynamic characteristics derived from microtremors. As a result, natural frequencies estimated by the microtremor records before the seismic reinforcement are approximately 25~30% bigger than those estimated by these records after the seismic reinforcement. The results show that the reinforcement method signi_cantly increases the sti_ness of a RC building. Furthermore, this paper presents the Structural Health Monitoring （SHM） system using Internet of Things （IoT） to improve for the earthquake disaster reduction and maintainability of buildings.</dc:description>
          <dc:description>departmental bulletin paper</dc:description>
          <dc:publisher>広島工業大学</dc:publisher>
          <dc:date>2023-02-05</dc:date>
          <dc:type>VoR</dc:type>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>広島工業大学紀要. 研究編</dc:identifier>
          <dc:identifier>57</dc:identifier>
          <dc:identifier>107</dc:identifier>
          <dc:identifier>114</dc:identifier>
          <dc:identifier>AA11599110</dc:identifier>