<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-08T14:13:45Z</responseDate>
  <request verb="GetRecord" identifier="oai:it-hiroshima.repo.nii.ac.jp:00000926" metadataPrefix="oai_dc">https://it-hiroshima.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:it-hiroshima.repo.nii.ac.jp:00000926</identifier>
        <datestamp>2023-07-25T10:37:08Z</datestamp>
        <setSpec>1:18:381</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>せん断パネルダンパーの2軸載荷下の抵抗性状に関する研究</dc:title>
          <dc:title>Resistance Mechanism of Shear Panel Damper under Bi-axial Shear Loading</dc:title>
          <dc:creator>玉井, 宏章</dc:creator>
          <dc:creator>タマイ, ヒロユキ</dc:creator>
          <dc:creator>尾川, 勝彦</dc:creator>
          <dc:creator>オガワ, カツヒコ</dc:creator>
          <dc:creator>Tamai, Hiroyuki</dc:creator>
          <dc:creator>Ogawa, Katsuhiko</dc:creator>
          <dc:subject>steel damper</dc:subject>
          <dc:subject>vibration-controlled structures</dc:subject>
          <dc:subject>bi-axial loading</dc:subject>
          <dc:subject>shear panel damper</dc:subject>
          <dc:description>application/pdf</dc:description>
          <dc:description>Shear panel steel damper (S.P.D.) are used as a hysteretic damper for building. Bracing and post type structure has adopted with the shear panel damper in Japan. Although post column with shear panel damper are subjected to bi-axial loading under severe earthquake, the restoring force characteristics of shear panel damper under biaxial loading are not clarified so far. Hence, we investigated the resistance mechanism of the damper under bi-axial shear loading. First, we introduced the shear stress distribution of panel and flange in S.P.D. to show resistance mechanism of S.P.D. under bi-axial shear loading. Secondary, elastic bi-axial loading tests were performed. to check the distribution Stiffness evaluation formula will be derived from the shear stress distribution.</dc:description>
          <dc:description>departmental bulletin paper</dc:description>
          <dc:publisher>広島工業大学</dc:publisher>
          <dc:date>2012-02</dc:date>
          <dc:type>VoR</dc:type>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>広島工業大学紀要. 研究編</dc:identifier>
          <dc:identifier>46</dc:identifier>
          <dc:identifier>159</dc:identifier>
          <dc:identifier>168</dc:identifier>
          <dc:identifier>AA11599110</dc:identifier>
          <dc:identifier>13469975</dc:identifier>
          <dc:identifier>https://it-hiroshima.repo.nii.ac.jp/record/926/files/kenkyuhen46159.pdf</dc:identifier>
          <dc:identifier>https://it-hiroshima.repo.nii.ac.jp/records/926</dc:identifier>
          <dc:language>jpn</dc:language>
          <dc:relation>40019182669</dc:relation>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>