<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-13T14:18:23Z</responseDate>
  <request verb="GetRecord" identifier="oai:it-hiroshima.repo.nii.ac.jp:00000375" metadataPrefix="jpcoar_2.0">https://it-hiroshima.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:it-hiroshima.repo.nii.ac.jp:00000375</identifier>
        <datestamp>2023-07-25T10:51:14Z</datestamp>
        <setSpec>1:17:187</setSpec>
      </header>
      <metadata>
        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/2.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/2.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/2.0/jpcoar_scm.xsd">
          <dc:title>探針によるディジタルフローベロシメータの開発</dc:title>
          <dc:title xml:lang="en">Development of Digital Flow Velocimeter by Using Probe</dc:title>
          <jpcoar:creator>
            <jpcoar:creatorName>玉野, 和保</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">タマノ, カズホ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">Tamano, Kazuho</jpcoar:creatorName>
          </jpcoar:creator>
          <datacite:description descriptionType="Other">application/pdf</datacite:description>
          <datacite:description descriptionType="Abstract">The paper describes a simple method of flow velocity measurement. This method has a merit that no calibration is required under the measuring conditions in order to apply for efficient measurement. The principle is based on application of electrolyzed material for at racer, which moves with the flow. The movement is represented numerically by a time interval when the tracer moves along the detecting electrode of the probe. The experiment confirming the principle and an example of application for a test channel are described.</datacite:description>
          <dc:publisher>広島工業大学</dc:publisher>
          <datacite:date dateType="Issued">1980</datacite:date>
          <dc:language>jpn</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_6501">departmental bulletin paper</dc:type>
          <oaire:version rdf:resource="http://purl.org/coar/version/c_970fb48d4fbd8a85">VoR</oaire:version>
          <jpcoar:identifier identifierType="URI">https://it-hiroshima.repo.nii.ac.jp/records/375</jpcoar:identifier>
          <jpcoar:sourceIdentifier identifierType="NCID">AN0021271X</jpcoar:sourceIdentifier>
          <jpcoar:sourceIdentifier identifierType="ISSN">03851672</jpcoar:sourceIdentifier>
          <jpcoar:sourceTitle>広島工業大学研究紀要</jpcoar:sourceTitle>
          <jpcoar:volume>14</jpcoar:volume>
          <jpcoar:pageStart>95</jpcoar:pageStart>
          <jpcoar:pageEnd>99</jpcoar:pageEnd>
          <jpcoar:file>
            <jpcoar:URI label="kenkyukiyo14095.pdf">https://it-hiroshima.repo.nii.ac.jp/record/375/files/kenkyukiyo14095.pdf</jpcoar:URI>
            <jpcoar:mimeType>application/pdf</jpcoar:mimeType>
            <jpcoar:extent>224.1 kB</jpcoar:extent>
            <datacite:date dateType="Available">2023-03-30</datacite:date>
          </jpcoar:file>
        </jpcoar:jpcoar>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
