<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-16T00:13:20Z</responseDate>
  <request verb="GetRecord" identifier="oai:it-hiroshima.repo.nii.ac.jp:00000816" metadataPrefix="jpcoar_1.0">https://it-hiroshima.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:it-hiroshima.repo.nii.ac.jp:00000816</identifier>
        <datestamp>2023-07-25T10:39:15Z</datestamp>
        <setSpec>1:18:378</setSpec>
      </header>
      <metadata>
        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/1.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/1.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/1.0/jpcoar_scm.xsd">
          <dc:title>せん断パネルダンパー付鉄骨架構の統合化耐震性能評価に関する研究</dc:title>
          <dc:title xml:lang="en">Collaborative Seismic Performance Evaluation of Steel Structure with Shear Panel Damper</dc:title>
          <jpcoar:creator>
            <jpcoar:creatorName>玉井, 宏章</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">タマイ, ヒロユキ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>高松, 隆夫</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">タカマツ, タカオ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>山西, 央朗</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">ヤマニシ, テルアキ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>多田, 元英</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">タダ, モトヒデ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">Tamai, Hiroyuki</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">Takamatsu, Takao</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">Yamanishi, Teruaki</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">Tada, Motohide</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:subject subjectScheme="NDC">524.6</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">collaborative seismic performance evaluation</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">shear panel damper</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">Internet</jpcoar:subject>
          <datacite:description descriptionType="Other">application/pdf</datacite:description>
          <datacite:description descriptionType="Abstract">In the previous paper, we improved a substructure online system for investigating the restoring force characteristics of exposed column-base. This substructure online system and interface of CSA ( Collaborative structural analysis ) forms a collaborative seismic performance evaluation system. This system enables collaboration among researchers by linking their programs and experimental systems through the Internet. As participants can shear data such as interactions between structural members, distribution of seismic loading and overall failure mode of building structures, it makes it very easy to investigate the seismic performance evaluation using the sophisticated knowledge of participants. Hence, we call it a collaborative seismic performance evaluation ( CSPE ). Also, the hysteretic damper is used to use the building frame in seismic area. In this paper, we evaluate the seismic performance of building frame with a shear panel dampers using this CSPE system. Evaluation results show validity and possibility of the presented CSPE system.</datacite:description>
          <dc:publisher>広島工業大学</dc:publisher>
          <datacite:date dateType="Issued">2009-02</datacite:date>
          <dc:language>jpn</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_6501">departmental bulletin paper</dc:type>
          <oaire:version rdf:resource="http://purl.org/coar/version/c_970fb48d4fbd8a85">VoR</oaire:version>
          <jpcoar:identifier identifierType="URI">https://it-hiroshima.repo.nii.ac.jp/records/816</jpcoar:identifier>
          <jpcoar:sourceIdentifier identifierType="NCID">AA11599110</jpcoar:sourceIdentifier>
          <jpcoar:sourceIdentifier identifierType="ISSN">13469975</jpcoar:sourceIdentifier>
          <jpcoar:sourceTitle>広島工業大学紀要. 研究編</jpcoar:sourceTitle>
          <jpcoar:volume>43</jpcoar:volume>
          <jpcoar:pageStart>241</jpcoar:pageStart>
          <jpcoar:pageEnd>247</jpcoar:pageEnd>
          <jpcoar:file>
            <jpcoar:URI label="kiyo43241.pdf">https://it-hiroshima.repo.nii.ac.jp/record/816/files/kiyo43241.pdf</jpcoar:URI>
            <jpcoar:mimeType>application/pdf</jpcoar:mimeType>
            <jpcoar:extent>1.1 MB</jpcoar:extent>
            <datacite:date dateType="Available">2023-03-30</datacite:date>
          </jpcoar:file>
        </jpcoar:jpcoar>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
